西門子數控(kong)車床維修,十年維修品(pin)質,專業技術,硬件故(gu)障快(kuai)速修復,全套測試平臺。
當我們(men)在使用(yong)數控(kong)車床的時(shi)候(hou)難免會遇到一些問題,等待(dai)機修維修的時(shi)間由比較長,如(ru)果我們(men)能掌握一些數控(kong)車床的維修技巧,那么,就不用(yong)浪(lang)費(fei)那么多時(shi)間等待(dai)別(bie)人(ren)來(lai)維修了。
機(ji)床(chuang)在運行時機(ji)床(chuang)照明燈突然不(bu)亮,機(ji)床(chuang)操作面板(ban)燈也不(bu)亮,系(xi)統(tong)電源(yuan)正常,同時系(xi)統(tong)急停報(bao)警,和主軸(zhou)無信號警。關機(ji)后(hou)重新上電故障依舊。
故障分析檢(jian)查:經詢問當時操(cao)作人(ren)員,沒(mei)有(you)(you)(you)違規操(cao)作,排除(chu)人(ren)為原因,也可以排除(chu)機(ji)械原因,應該是電(dian)(dian)氣故障引起(qi)。該機(ji)床的電(dian)(dian)器原理圖顯示,這些(xie)失電(dian)(dian)區域都(dou)和24V有(you)(you)(you)關,并(bing)且該機(ji)床擁(yong)有(you)(you)(you)兩個(ge)(ge)穩(wen)壓電(dian)(dian)源,一(yi)個(ge)(ge)是I/O接口電(dian)(dian)源,另一(yi)個(ge)(ge)為系統(tong)電(dian)(dian)源。失電(dian)(dian)區域都(dou)與I/O接口有(you)(you)(you)關,于是打開電(dian)(dian)氣柜觀察發(fa)現I/O接口穩(wen)壓電(dian)(dian)源指示燈未(wei)能(neng)點(dian)亮,說明該電(dian)(dian)源未(wei)能(neng)正常工(gong)作或(huo)損壞(huai)。
由穩壓電(dian)源(yuan)(yuan)的(de)工(gong)作(zuo)原理知道,穩壓電(dian)源(yuan)(yuan)有電(dian)流短路和過載(zai)保護的(de)功能,當電(dian)源(yuan)(yuan)短路或(huo)過載(zai)時自動關(guan)斷電(dian)源(yuan)(yuan)輸出(chu),以(yi)保護電(dian)源(yuan)(yuan)電(dian)路不(bu)(bu)被(bei)損(sun)壞(huai)。于是試著把電(dian)源(yuan)(yuan)的(de)輸出(chu)負(fu)載(zai)線路拆下來,結(jie)果發現(xian)重新上電(dian)后電(dian)源(yuan)(yuan)指示燈亮了(le)。這說明電(dian)源(yuan)(yuan)本身沒有損(sun)壞(huai)。通過分析得知該電(dian)源(yuan)(yuan)為(wei)I/O接口(kou)電(dian)源(yuan)(yuan),負(fu)載(zai)不(bu)(bu)大,也不(bu)(bu)會出(chu)現(xian)過載(zai)現(xian)象(xiang),應該是輸出(chu)回路中(zhong)有短路故障。沿著輸出(chu)線號進行檢查發現(xian)有一(yi)根(gen)24V+輸出(chu)線接頭(tou)從絕緣膠布(bu)中(zhong)露出(chu)并接觸到機床床體。
原因很(hen)明顯:由于該(gai)線與機床發生對地(di)短路,造成該(gai)穩壓電源處于自(zi)我保護狀(zhuang)態,使得操(cao)作面板(ban)和一些I/O接(jie)口繼電器(qi)供電停止,導致發生以上(shang)故(gu)障。至于變頻器(qi)報警可能(neng)24號不能(neng)到位發出報警。
解(jie)決辦法:用絕緣膠布把接(jie)頭(tou)處重新(xin)包好,重新(xin)上電開(kai)機所有故障(zhang)解(jie)決,報(bao)警(jing)解(jie)除(chu)照明燈也(ye)亮了。
上海恒稅電氣有限公司 版權所有 ICP備:GoogleSitemap 技術支持: