西門子直流調速裝置上電就跳閘-二小時好;SIEMENS維(wei)修(xiu)廠(chang)家,上(shang)海恒稅電氣有限公司,你(ni)的選擇沒有錯。公司自成立以來,長期(qi)銷售維(wei)修(xiu)西門子變(bian)頻器(qi)及(ji)伺服驅動器(qi)的,觸摸屏,PLC,直(zhi)流調速器(qi)等,積(ji)累了豐富的維(wei)修(xiu)經(jing)驗,對所(suo)維(wei)修(xiu)的機(ji)(ji)器(qi)建立完(wan)(wan)善的維(wei)修(xiu)檔案,所(suo)有我們維(wei)修(xiu)的機(ji)(ji)器(qi)我們都(dou)有完(wan)(wan)善的參(can)數備份,確保我們維(wei)修(xiu)的機(ji)(ji)器(qi)上(shang)機(ji)(ji)即能使用。
西門子直流調速裝置上電就跳閘-二小時好;
維修(xiu)起來可就沒(mei)那(nei)么順(shun)利了。先是(shi)維修(xiu)開關電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)源,主(zhu)要元件無一(yi)幸(xing)免,通(tong)(tong)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)試機后發(fa)(fa)(fa)現(xian)檢測比較器(qi)(qi)全(quan)部(bu)冒(mao)煙,更(geng)換后測量+24V,+15V,-15V,+5V均已(yi)修(xiu)復(fu),接(jie)主(zhu)板(ban)后顯示(shi)屏不亮,面板(ban)指示(shi)燈長亮,測量主(zhu)板(ban)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓正(zheng)常,CPU嚴重(zhong)發(fa)(fa)(fa)熱(re),只(zhi)好更(geng)換主(zhu)板(ban)。更(geng)換主(zhu)板(ban)后接(jie)通(tong)(tong)220V工作電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)源,顯示(shi)CALIBRATION FAIL校準失敗,然后約半分鐘后觸發(fa)(fa)(fa)板(ban)100歐電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)冒(mao)煙,正(zheng)常情況下直流(liu)調速器(qi)(qi)這(zhe)個(ge)(ge)(ge)時候應該(gai)要顯示(shi)正(zheng)常,不發(fa)(fa)(fa)熱(re)不報警的, 清理(li)線路(lu)(lu)后結果如下,主(zhu)板(ban)觸發(fa)(fa)(fa)芯(xin)片2003輸出(chu)導通(tong)(tong)信號,經(jing)過(guo)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)源板(ban)的十二顆標(biao)記(ji)053的三極管(NPN,基極觸發(fa)(fa)(fa)后將集(ji)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)極對地(di),集(ji)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)極接(jie)的是(shi)脈沖變(bian)壓器(qi)(qi)的一(yi)個(ge)(ge)(ge)引腳(jiao)(jiao),另一(yi)個(ge)(ge)(ge)引腳(jiao)(jiao)通(tong)(tong)過(guo)100歐電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)接(jie)通(tong)(tong)24伏),放大(da)導通(tong)(tong)脈沖變(bian)壓器(qi)(qi),跟(gen)功放輸出(chu)繼電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)器(qi)(qi)一(yi)個(ge)(ge)(ge)控(kong)制方式。可逆(ni)式電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)源板(ban)插座(zuo)排列:兩端共8個(ge)(ge)(ge)引腳(jiao)(jiao)是(shi)+24V,中間兩排共12個(ge)(ge)(ge)引腳(jiao)(jiao)為(wei)觸發(fa)(fa)(fa)脈沖,不可逆(ni)小插座(zuo):右側4個(ge)(ge)(ge)引腳(jiao)(jiao)為(wei)+24V,左側6個(ge)(ge)(ge)引腳(jiao)(jiao)為(wei)脈沖。發(fa)(fa)(fa)熱(re)冒(mao)煙的原因是(shi)其(qi)中一(yi)跟(gen)三極管短路(lu)(lu),相當開脈沖變(bian)壓器(qi)(qi)初級(ji)得到(dao)了24V直流(liu)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓,所以限流(liu)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)會過(guo)熱(re)冒(mao)煙。
將(jiang)三(san)極(ji)管更換后試(shi)機(ji),顯示(shi)器報(bao)警ACCTS 故(gu)障(zhang)(zhang)(ACCTS FAILED),故(gu)障(zhang)(zhang)報(bao)警意思為(wei)電流(liu)傳感(gan)器異常,但(dan)是此時三(san)個(ge)電流(liu)傳感(gan)器都已經接好,線(xian)(xian)路也沒(mei)有(you)開路,三(san)個(ge)電流(liu)傳感(gan)器有(you)三(san)個(ge)引(yin)腳相連,另外(wai)三(san)個(ge)引(yin)腳送到藍色主板插頭(tou)旁(pang)邊的(de)六只二(er)極(ji)管形(xing)(xing)成三(san)相橋式整流(liu),通過LM324比較檢(jian)測。更換LM324后ACCTS FAILED故(gu)障(zhang)(zhang)消(xiao)失。開關變壓(ya)器上邊三(san)個(ge)指示(shi)燈(deng):FLD HS OT ,ARM HS OT ,PHASE LOSS,分(fen)(fen)別是勵(li)磁(ci)超溫,電樞超溫,三(san)相電平低報(bao)警。當兩(liang)(liang)個(ge)溫度燈(deng)異常點亮(liang)時測試(shi)方法:溫度線(xian)(xian)插頭(tou)外(wai)的(de)兩(liang)(liang)顆圓形(xing)(xing)貼片(pian)電阻100歐兩(liang)(liang)端(duan)分(fen)(fen)別對地,1001(1K)方形(xing)(xing)貼片(pian)電阻為(wei)檢(jian)測腳,此時如果兩(liang)(liang)個(ge)溫度燈(deng)還異常亮(liang)起,說明(ming)檢(jian)測電路壞了(le)。
西門子直流調速裝置上電就跳閘-二小時好;西門子6RA70直流調速(su)器的(de)弱磁(ci)設置完事(shi)方(fang)法。
1 . 系統設(she)定值(zhi)復(fu)位(wei)及偏差調整
?? 用PMU 執行功能P051= 21,或(huo)在PC 中調用缺(que)省的工(gong)廠設置參數構成基本
參(can)數(shu)(shu)(shu)文件,凡是(shi)下(xia)文中(zhong)未提(ti)到的參(can)數(shu)(shu)(shu)都(dou)利用缺(que)省參(can)數(shu)(shu)(shu),參(can)數(shu)(shu)(shu)值見(jian)手冊,用
P052=0 顯示那些與初始工(gong)廠設置不同(tong)的參數。
?? 合上裝(zhuang)置控(kong)制(zhi)電源和操作控(kong)制(zhi)電源執(zhi)行(xing)P051=21,偏差(cha)調整(P051=22)同(tong)時
進行(xing),參數P825.02 被(bei)設置(zhi)。
2 . 整 流 裝 置 參 數(shu) 設(she) 定
?? P067=1-5 選擇負載過(guo)負荷周期,見手冊,當本參數(shu)大(da)于1 時,整流器額定
2
直流電流R072.01 將變為所選周期內(nei)的基(ji)本負載(zai)值,P075 參(can)數必(bi)須設定為
1 或2。一般情況下(xia),裝置的(de)計(ji)算的(de)晶閘管溫升包容上述(shu)過載(zai)周期
?? P075=0 不允許(xu)裝置過載, 裝置最大輸(shu)出電(dian)流被限制在額(e)定直流電(dian)流
R072.01
?? =1 電(dian)(dian)樞電(dian)(dian)流(liu)最大值(zhi)被限制(zhi)在(zai)P077*1.8*整流(liu)器額定直流(liu)電(dian)(dian)流(liu)R072.01,當計
算的晶閘管溫升(sheng)超(chao)過(guo)允許值時(shi),報(bao)警A039 激活,電(dian)樞電(dian)流給(gei)定自(zi)(zi)動(dong)(dong)自(zi)(zi)動(dong)(dong)減
小到(dao)整流器額(e)定電流R072.01。
?? =2 整(zheng)流器電(dian)樞電(dian)流最大(da)值被限制在 P077*1.8* 整(zheng)流器額定直流電(dian)流
R072.01,當計算的(de)晶閘管溫(wen)升超(chao)過允許值(zhi)時,故(gu)障F039 被(bei)激活。
?? 本參數(shu)(shu)根(gen)據電機額定(ding)參數(shu)(shu)值和使用(yong)工況(kuang),從(cong)保護裝置過載的角度出(chu)發進行設(she)
置(zhi),本參(can)數與(yu)P067 共同作用,對(dui)裝置(zhi)的過負荷周期進行(xing)設(she)定。
?? P078.01= 630V 主回路進線交流電(dian)壓,作為判斷電(dian)壓故障(zhang)的基準值
?? P078.02= 380V,勵磁進線電壓
?? 作為欠壓或過壓的判斷門檻電壓,相關參數見P351,P352,P361-P364.
3 . 電機參數(shu)設定
?? P100(F)= 額定電(dian)(dian)(dian)動機電(dian)(dian)(dian)樞電(dian)(dian)(dian)流(A)
?? P101(F)=額定電動機電樞(shu)電壓(V)
?? P102(F)= 額定電動機勵磁(ci)電流(liu)(A)
?? P103(F)=最小電機(ji)勵磁電流(A),必須小于 P102 的50%.在弱磁調(diao)速場合,一(yi)
般設定到防止失磁(ci)的數(shu)值.